LOAD CONTROL
SWITCHES
|
|
|
|
   
|
|
The i-LiNE load control
switches have been designed to provide local control over lights and
motors. The two basic load switches are the i-ON relay ON/OFF switch
and the i-ON-D dimmer switch. In addition, the i-ON-Dlv low-voltage
dimmer switch is now shipping.
The i-LiNE load control switches have been designed to comply
with Underwriters Laboratories (UL) and National Electrical Code
(NEC) specifications. See below for details of the applicable
NEC code specifications.

Load Control Switches |

|
|
|
|
LOAD CONTROL SWITCHES
OVERVIEW |
|
230VAC, 50Hz
Switches Now Available |
|
 |
i-ON
- Relay Load Control Switch, 600 Watts, 120VAC, 60Hz and
230VAC 50Hz.
Elegant flush mounted switch. Available in White, Almond, Ivory,
and Custom Colors*.
Additional Details |
|
|
 |
i-ON-R
- High Power Relay Load Control Switch, 1500 Watts, 120VAC, 60Hz
and 230VAC 50Hz.
Elegant flush mounted switch. Available in White, Almond, Ivory,
and Custom Colors*.
COMING SOON
Additional Details |
|
|
 |
i-ON-D
- Dimmer Load Control Switch, 600 Watts, 120VAC, 60Hz and
230VAC 50Hz.
Elegant flush mounted switch. Available in White, Almond, Ivory,
and Custom Colors*.
Additional Details |
|
|
 |
i-ON-Dmlv
- Magnetic Low Voltage Dimmer Load Control Switch, 600 VA/Watts,
120VAC, 60Hz and 230VAC 50Hz. Elegant flush mounted switch. Available in White,
Almond, Ivory, and Custom Colors*.

Additional Details |
|
|
 |
i-ON-F - Ceiling Fan
Six Speed Control Switch, 5 Amps, 120VAC, 60Hz and 230VAC 50Hz. Elegant
flush mounted switch. Available in White, Almond, Ivory, and
Custom Colors*. 
Additional Details |
|
|
 |
i-ON-L
- 2-Wire Relay Load Control Switch, 1500 Watts, 120VAC, 60Hz and
230VAC 50Hz (Also can control DC voltages and other AC voltages).
Elegant flush mounted switch. Available in White, Almond, Ivory,
and Custom Colors*.
COMING SOON
Additional Details |
|
|
 |
i-ON-LS
- 2-Wire Relay Load Control Switch with Sensor Input Contacts,
1500 Watts, 120VAC, 60Hz and 230VAC 50Hz (Also can control DC
voltages and other AC voltages).
Elegant flush mounted switch. Available in White, Almond, Ivory,
and Custom Colors*.
COMING SOON
Additional Details |
|
|
IMPORTANT NOTICE
Attention
Installers and Inspectors
This device has been designed to
comply with the National Electrical Code concerning the use of low
voltage cabling in the same enclosure as 120 VAC cable. The i-LiNE
device network connecting cable MUST have a jacket insulation rating
of 120 VAC or greater and be UL listed. Please refer to the NEC code
Chapter 3 Section 300.3(c)(1) for additional information.
NEC 300.3(c)(1)
(C) Conductors of Different Systems.
(1) 600 Volts, Nominal or Less.
Conductors of circuits rated 600 volts, nominal, or less, ac
circuits, and dc circuits shall be permitted to occupy the same
equipment wiring enclosure, cable, or raceway. All conductors shall
have an insulation rating equal to at least the maximum circuit
voltage applied to any conductor within the enclosure, cable, or
raceway.
NEC 725.55(D)
(D) Associated Systems Within
Enclosures. Class 2 and Class 3 circuit conductors in compartments,
enclosures, device boxes, outlet boxes, or similar fittings shall be
permitted to be installed with electric light, power, Class 1,
non-power-limited fire alarm, and medium power network-powered
broadband communications circuits where they are introduced solely
to connect the equipment connected to Class 2 and Class 3 circuits,
and where (1) or (2) applies:
(1) The electric light, power, Class
1, non-power-limited fire alarm, and medium power network-powered
broadband communications circuit conductors are routed to maintain a
minimum of 6 mm (0.25 in.) separation from the conductors and cables
of Class 2 and Class 3 circuits.
(2) The circuit conductors operate at 150 volts or less to ground
and also comply with one of the following: a. The Class 2 and Class
3 circuits are installed using Type CL3, CL3R, or CL3P or permitted
substitute cables, provided these Class 3 cable conductors extending
beyond the jacket are separated by a minimum of 6 mm (0.25 in.) or
by a nonconductive sleeve or nonconductive barrier from all other
conductors. b. The Class 2 and Class 3 circuit conductors are
installed as a Class 1 circuit in accordance with 725.21.
|
|